Files
philips-tv-speicher-voll/patches/adopted-storage/FAILURE-MATRIX.md

1.4 KiB

Selective adopted-storage failure matrix

Event Required behavior Forbidden outcome
USB absent at boot Open internal channel/Now/Next DB; schedule cache empty/reacquires boot/provider crashloop
Removal during read cancel cursor, close external pool, retry against internal minimum stale FD loop or TV UI ANR
Removal during write rollback/discard incomplete external generation promote partial DB
Slow/failing fsync trip latency/I/O circuit breaker and fall back internal block Live TV thread
External full stop cache acquisition, retain internal authority internal low-space warning caused by USB
Corrupt DB/sentinel quarantine generation logically and rebuild later attach/open as authoritative
Reinsert same UUID verify schema, integrity and generation before use blind reopen
Different/reformatted UUID initialize a new cache trust old pointer
Factory reset forget pointer/key and recreate internal minimum require removed USB to boot
OTA/schema change migrate a copy or discard/reacquire cache in-place irreversible migration without fallback
Standby/power loss recover last committed generation cross-volume atomicity assumption

The external payload is reconstructible cache only. Channel numbering, favorites, recordings, timers, reminders, credentials and the minimal provider schema remain internal.